LEED certification

LEED v5 metering and monitoring credits, backed by live data

LEED is the US Green Building Council's voluntary green building rating, certified through GBCI. In LEED v5, energy and water metering are prerequisites with five years of reporting, and several credits score continuous monitoring. Aqueduct supplies the meters' data and the indoor air record.

Powered by aQ Assure, aQ EnergySmart and aQ AirSafe
Condenser fans seen from above
Site performance · this quarter
-8.4% vs expected
Weather normalizedBelow baseline
Demo data
Peak demand today
612 kW
Contracted 650 kWChillers sequenced
Demo data

Who it applies to

Owners who choose to certify, at Certified, Silver, Gold or Platinum. LEED v5 has rating systems for new construction and core and shell (BD+C), interiors (ID+C) and existing buildings (O+M), each worth up to 110 points.

v5 launched in 2025 and moves more weight onto measured performance. For BD+C projects registered from 1 January 2028, the energy prerequisites reference ASHRAE 90.1-2022.

LEED v5

Prerequisites and credits that need measured data

Codes and points from the LEED v5 BD+C and O+M rating systems, July 2026. Your LEED consultant submits and GBCI reviews.

RequirementWhat it asks forData Aqueduct supplies
BD+C EAp4, Energy Metering and Reporting (required)Energy monitored per ASHRAE 90.1, with 12 months of energy by source and peak demand reported to USGBC each year for five years.Interval data per source and end use, with yearly exports.
BD+C WEp1, Water Metering and Reporting (required)Permanent whole-project meters for potable and alternative water, shared yearly for five years.Main water meters read continuously.
BD+C WEc1, Water Metering and Leak Detection (1 point)Submeters on at least 80 percent of indoor fixtures and major uses, recorded at least hourly; or leak detection sensors.Water sub-meters and leak alerts by zone.
BD+C EAc5, Enhanced CommissioningOption 2: at least three years of monitoring-based commissioning on an energy information system.Metered data and fault detection on the systems being commissioned.
O+M EAp2, Energy Monitoring and Reporting (required)Permanent meters for each energy source and monthly data for the 12-month period.Monthly totals per source from metered data.
O+M EQc1, Indoor Air Quality Performance (up to 10 points)At least 3 months of continuous monitoring, hourly or faster (15 minutes for CO2), scored on CO2, PM2.5 and TVOC.CO2, PM2.5 and TVOC per zone at 15 minute intervals or finer.
By the numbers

Thresholds that score

800 ppm

CO2 at the 95th percentile that earns the full 4 CO2 points in O+M EQc1; PM2.5 earns up to 4 points at 12 µg/m3.

Source: LEED v5 O+M rating system
1 Jan 2028

New BD+C registrations must use ASHRAE 90.1-2022 for the energy prerequisites.

Source: LEED v5 BD+C rating system
Standards and regulations

Related standards

Trusted at scale
Read the case studies
Deployed275+

sites in 21 countries run on Aqueduct.

Healthcare22 hospitals

and 9 clinics in one of India’s top hospital chains.

AirportsA top 25

US airport running water intelligence on Aqueduct.

Real estate20M+ sq ft

of commercial real estate under Aqueduct.

Manufacturing300 acres

FMCG manufacturing campus.

Food and dairyMajor dairy

operations run on Aqueduct.

Questions

Common questions

For BD+C, the metering prerequisites require energy and water data to be shared with USGBC every year for five years. The meters have to keep working and someone has to export the data, which Aqueduct produces as a yearly export per source.

Not as a separate credit in v5 BD+C. Metering sits in prerequisite EAp4, and monitoring-based commissioning in EAc5 builds on the same data over at least three years. Aqueduct can supply that monitoring, with fault detection on the commissioned systems.

aQ AirSafe measures the CO2, PM2.5 and TVOC that EQc1 scores, at the intervals the credit asks for. Your LEED consultant confirms that the sensor specification and placement meet the credit before the monitoring period starts. See IAQ monitoring.

Yes, as an alternative route in WEc1 for BD+C, worth one point, alongside hourly submetering of indoor fixtures and major uses. Aqueduct can supply either route, from hourly readings per sub-meter to flow alarms located to an area. See leak detection.

See Aqueduct on your own facility.

Bring a site, a utility bill or a question. We will show you where the loss is.