Dubai Al Sa'fat

Al Sa'fat metering and air quality, from design into operation

Al Sa'fat is Dubai Municipality's green building system. Every new building must reach Silver Sa'fa, which includes electricity, cooling and water metering, and some existing buildings must test indoor air. Aqueduct reads those meters and sensors and keeps the records.

Powered by aQ Assure, aQ EnergySmart and aQ WaterGuard
Control panel switches
Device health
ERS-CO2 · Level 2, Zone 4
Connection reliability99.2%
Battery3.61 V
Last reading1 min ago
Demo data
How does this week compare to the last few weeks?
12% below last week, driven by lower HVAC load on weekday afternoons. Two days had low meter coverage.
Demo data

Who it applies to

Since 19 October 2020, Al Sa'fat has replaced the Dubai Green Building Regulations. All new buildings, from villas to commercial and public buildings, must obtain Silver Sa'fa. Golden and Platinum Sa'fa are voluntary. The current text is the second edition, January 2023.

Some clauses reach existing buildings too: indoor air quality testing for hotels, malls, schools, healthcare and government buildings, and re-commissioning for large cooling plants.

Second edition, 2023

Clauses that need measured data

Clause numbers from Al Sa'fat, Dubai Green Building System, second edition. Dubai Municipality approves compliance.

RequirementWhat it asks forData Aqueduct supplies
503.03, electricity meteringWhole-building electricity demand and consumption metered and recorded.Main and sub-meter interval data by building and floor.
503.04, air conditioning meteringChilled water metered where a chiller plant or district cooling serves several consumers.BTU meters per consumer, read over Modbus or M-Bus.
503.05, CCMSA central control and monitoring system for buildings with 1 MW of cooling or 5,000 m2 or more.BMS and meter data on one model, with faults and trends.
602.01, water meteringDEWA-approved meters, sub-meters on major uses and tenancies, real time profiling and no run-hour virtual meters; records kept five years.Water sub-meters per use and tenant in a live balance, with five-year history.
401.07, IAQ in existing buildingsTesting against limits including CO2 below 800 ppm, TVOC below 300 micrograms/m3 and formaldehyde below 0.08 ppm.Continuous CO2, TVOC and particulate readings per zone between tests.
503.02, re-commissioningExisting buildings with 2 MW or more of cooling re-commissioned at least every five years.Plant performance trends that show where re-commissioning is due.
Standards and regulations

Related standards

Trusted at scale
Read the case studies
Deployed275+

sites in 21 countries run on Aqueduct.

Healthcare22 hospitals

and 9 clinics in one of India’s top hospital chains.

AirportsA top 25

US airport running water intelligence on Aqueduct.

Real estate20M+ sq ft

of commercial real estate under Aqueduct.

Manufacturing300 acres

FMCG manufacturing campus.

Food and dairyMajor dairy

operations run on Aqueduct.

Questions

Common questions

No, not in the current second edition. The levels are Silver Sa'fa, which every new building must reach, and the voluntary Golden and Platinum Sa'fa, which add requirements on top of it.

Consumption per major use and tenancy over time, kept for five years. Interval data from physical meters also makes leaks visible within hours, which estimates from pump run hours cannot.

The clause asks for metering integrated with the BMS or CCMS. Aqueduct reads wired and LoRaWAN meters and brings them into one model, subject to DEWA approval of the meter itself.

Under clause 401.07, hotels, malls, schools, healthcare and government buildings test indoor air against set limits. Between those tests, aQ AirSafe keeps a continuous indoor air record for each zone, so a single result can be checked against months of readings. See IAQ monitoring.