Glossary
FMCG and manufacturing

What is Compressed air leaks?

Definition

Compressed air leaks are unintended escapes of air from pipes, hoses, fittings, regulators and drains in an industrial air system, which force compressors to run longer to hold pressure.

Where leaks occur

Any plant with a compressed air network, from packaging and bottling to dairies and automotive suppliers, has some leakage. The US Department of Energy compressed air sourcebook names couplings, hoses, tubes and fittings, pressure regulators, open condensate traps and shut-off valves, and pipe joints, disconnects and thread sealants as the most common problem areas.

How leakage is estimated

For compressors with start and stop or load and unload controls, DOE describes a no-demand test: with all air-using equipment off, time the loaded and unloaded periods. Leakage as a share of compressor capacity equals on-load time divided by the sum of on-load and off-load time. DOE puts leakage in a well-maintained system below 5 to 10 percent, and in poorly maintained systems as high as 20 to 30 percent of air capacity and power.

Finding leak load in Aqueduct data

A compressor's electricity meter tells most of the story. Aqueduct compares compressor kW during non-production hours, when demand should be close to zero, against the same hours in the baseline, so rising night and weekend load flags new leaks between surveys. Load disaggregation separates compressors from other loads on a shared feeder where they are not metered individually.

Questions

Compressed air leaks: common questions

A compressed air leak is any point where air escapes from a plant's air network without doing useful work. Leaks are often silent and spread across many fittings, so they waste compressor energy around the clock. Aqueduct's view is on the compressed air and steam page.

There is no single required interval. Trending off-shift compressor power shows when leakage climbs, so an ultrasonic survey can be scheduled when it pays rather than only by calendar.

Yes. DOE notes that leaks lower system pressure so air tools work less efficiently, lengthen compressor run time and shorten equipment life, and can lead a plant to buy compressor capacity it does not need.

See Aqueduct on your own facility.

Bring a site, a utility bill or a question. We will show you where the loss is.