Definition

Biochemical oxygen demand (BOD) and chemical oxygen demand (COD) measure how much oxygen the organic matter in wastewater would consume, biologically and chemically. They are the main measures of effluent strength.

Who tests BOD and COD

Any plant that discharges process wastewater, including dairies, food and beverage plants, distilleries and textile units, reports both to its pollution regulator. ETP and STP operators also use them daily to judge whether the biological stage is coping with its load.

Test methods and limits in India

BOD is a biological test. In India it is measured over 3 days at 27 degrees Celsius, which replaced the older 5 day test at 20 degrees Celsius through a 1996 amendment to the Environment (Protection) Rules, 1986. COD uses a strong chemical oxidant and returns a result within hours.

Schedule VI of those rules sets general BOD limits of 30 mg per liter for inland surface water, 350 mg per liter for public sewers and 100 mg per liter for land irrigation or marine coastal discharge. COD is capped at 250 mg per liter for inland surface water and marine coastal areas. Sector standards can differ, and the consent issued by the state board is what binds a plant.

Where Aqueduct's water data meets BOD

Aqueduct does not run lab tests. Where an online analyzer exists, its readings sit on the water digital twin beside flow, and the STP block already shows BOD out in mg per liter. Multiplying concentration by metered flow turns a lab value into a load in kilograms per day, the figure that explains when the biological stage is overloaded.

Questions

BOD and COD: common questions

BOD and COD are the two standard laboratory measures of how polluting wastewater is. Regulators write discharge limits in them, and treatment plant operators use them to size and run biological treatment. Aqueduct pairs them with metered flow on the effluent and ETP page.

The chemical oxidant breaks down organic matter that bacteria digest slowly or not at all. The ratio between the two therefore hints at how biodegradable an effluent is.

Not where the consent lists both. Many plants use COD for daily process control because it is quick, and send BOD samples to a lab for the returns the consent requires.

See Aqueduct on your own facility.

Bring a site, a utility bill or a question. We will show you where the loss is.