Ways in: keep your BMS

Keep your BMS. Add what it cannot see.

If your BMS works, keep it. Aqueduct reads its points over BACnet or Modbus, adds the water, energy and air metering most BMS installations never had, and works across it.

Condenser fans seen from above
Site performance · this quarter
-8.4% vs expected
Weather normalizedBelow baseline
Demo data
Command history · RTU-2
Occupied mode07:00 · executed
Economizer on07:12 · executed
Lockout active07:13 · held
Demo data
Division of work

What stays and what is added.

Your BMS keepsAqueduct adds
EquipmentSequences, schedules and alarmsDiagnosis of which component failed, routed to your CMMS
MeteringThe points it already readsSub-meters for water, electricity and gas, and air sensors per zone
ResultsTrend logsWeather-normalized baselines and savings in money
How it runs

Four steps, no rip and replace.

01

Survey

Map the BMS points, existing meters and the gaps.

02

Connect

Read BMS points over BACnet or Modbus through a field device network controller.

03

Fill gaps

Add LoRaWAN meters and sensors where the BMS has no data, installed through partners.

04

Act

Faults go to your CMMS. Setpoint and schedule changes run where control is enabled, with owner approval.

By the numbers

What sits unused in most BMS installations.

29%

potential cut in US commercial building energy from well-tuned controls, in a PNNL simulation.

Source: PNNL via US DOE
40%

of air handlers had a reported fault on any given day in an LBNL study of 60,000+ pieces of equipment.

Source: LBNL, 2023

When keeping stops making sense

If the BMS is out of support, its controllers can no longer be programmed, or it cannot share its data over an open protocol, compare the cost of keeping it with replacing it.

Questions

Common questions

No. The BMS keeps running its sequences, schedules and alarms, and Aqueduct only reads its points until the owner turns control on for specific equipment. Even then, every command is logged with whether it executed. See trust and security.

Usually a field device network controller that reads BMS points over BACnet or Modbus. LoRaWAN meters and air sensors then fill the gaps where the BMS has no data. Existing meters join if they send telemetry, so nothing that works is replaced. See controllers and actuators.

Brand matters less than access. Aqueduct works with any BMS that exposes its controllers over BACnet or Modbus, and the site survey confirms which points can be read before anything is installed. See the protocols Aqueduct speaks.

Yes. Aqueduct compares what each air handler or rooftop unit was commanded to do with what its BMS points report, then names the failed component and sends a work order to your CMMS. The BMS alarm list stays as it is. See fault detection and diagnostics.

See Aqueduct on your own facility.

Bring a site, a utility bill or a question. We will show you where the loss is.