ASHRAE 170

ASHRAE 170 room conditions, logged space by space

ASHRAE/ASHE Standard 170 sets ventilation design for health care spaces: pressure, air changes, filtration, humidity and temperature by room type. Surveyors then ask whether rooms still perform as designed. Aqueduct logs pressure, temperature, humidity and air handler status per room and flags every excursion.

Powered by aQ Assure and aQ AirSafe
Ceiling air unit under a glass roof
Hall B · occupied
1,184 ppm CO₂
Ventilation adjusted
Demo data
Site air health · 24h
Unhealthy, driven by CO₂
Over 2000 ppm for 20+ minutes within an occupied hour. Increase ventilation, raise outdoor air supply or check the AHU economizer.
3 of 4 zones breaching · outdoor 67°F
Demo data

Who it applies to

Hospitals and outpatient facilities in their design and renovation. The current edition is 170-2025. For existing US hospitals, CMS and The Joint Commission enforce it indirectly, through the health care facilities code. Which edition applies depends on the authority having jurisdiction.

Tables 7-1 and 8-1

Design parameters that need operating records

Values from published addenda to 170-2021 and 170-2025. Your engineers and accrediting body decide compliance.

RequirementWhat it asks forData Aqueduct supplies
Operating room (Table 7-1)Positive pressure, 4 outdoor and 20 total air changes per hour, MERV-16, 20 to 60 percent RH, 68 to 75°F.Differential pressure, temperature and humidity per room, with excursions timestamped.
Airborne infection isolation (Table 8-1)Negative pressure, 12 total air changes, all air exhausted outdoors, RH at most 60 percent.Room pressure monitors read continuously, with reversals flagged.
Protective environment (Table 8-1)Positive pressure, 12 total air changes, HEPA filtration.Pressure and filter differential points from the BMS.
Air changesSupply and exhaust airflow meeting the design rate for each space.Airflow points trended per room where the BMS has them; test and balance stays with your contractor.
Operational changes, note ii (2026)A documented risk assessment before ventilation is adjusted, kept in a ventilation management plan.Before and after records for any change to a room's air.
By the numbers

What changed in 2026

521 ORs

Operating rooms in 45 hospitals where higher ventilation did not lower surgical site infection, cited in addendum y, which adds the risk assessment rule.

Source: ASHRAE 170-2025 addendum y
Standards and regulations

Related standards

Joint CommissionASHRAE 62.1 ASHRAE 188 NABH
Trusted at scale
Read the case studies
Deployed275+

sites in 21 countries run on Aqueduct.

Healthcare22 hospitals

and 9 clinics in one of India’s top hospital chains.

AirportsA top 25

US airport running water intelligence on Aqueduct.

Real estate20M+ sq ft

of commercial real estate under Aqueduct.

Manufacturing300 acres

FMCG manufacturing campus.

Food and dairyMajor dairy

operations run on Aqueduct.

Questions

Common questions

No. ASHRAE 170 sets design values for each room type rather than monitoring rules. Continuous room records are how a hospital shows those values still hold between surveys and rebalancing, and Aqueduct logs each room so any drift has a date and a duration.

Only with owner approval, and many hospitals keep critical rooms read-only. Under the 2026 note, any change to space ventilation needs a documented risk assessment first, so Aqueduct logs the readings either side of any adjustment the hospital approves.

For CMS-certified hospitals, the one referenced through NFPA 99-2012, which is 170-2008. New projects follow the edition the local code or FGI Guidelines adopt, so one hospital can hold rooms built to different editions, and Aqueduct stores the limits per room.

Yes. Aqueduct flags the moment an airborne infection isolation room loses its negative relationship to the corridor. The alert carries the room, the duration and the air handler state at the time, so engineering starts from the likely cause. See Joint Commission PE.

See Aqueduct on your own facility.

Bring a site, a utility bill or a question. We will show you where the loss is.