aQ Resilience · For data centers

How much more load can your data center safely carry?

aQ Resilience joins power, cooling, water and IT load into one live view. It shows the capacity that survives any single failure, what breaks if a unit goes down, and what to change next, with your team approving every change.

Built on Milvian AI's platform (Aqueduct) · 300+ live sites · SOC 2 Type 2 · ISO/IEC 27001
UPS roomHall 1Hall 2Chiller plantCRAH-2 in maintenance
Resilient headroom · Hall 10.30 MWAll units availableIllustrative
Path APath BChilled water
The problem

A data center can never stop. Its data lives in three places.

Cooling sits in the BMS. Power, racks and space sit in the DCIM. Water sits in a spreadsheet, or nowhere. So the questions that matter most are the hardest to answer.

Are we safe?

If a UPS, chiller or CRAH fails now, can we still carry today's load?

Are we efficient?

Where are energy and water wasted, and what is it worth?

What should we do next?

What happens if we add GPU racks, take a chiller out, or hit a heatwave?

56%

of operators with an outage say power caused their worst one.

Uptime Institute, 2026
76%

of operators worry about forecasting capacity.

Uptime Institute, 2026
89%

say their outage was preventable with better process.

Uptime Institute, 2026
1.52

average PUE, after seven years of little change.

Uptime Institute, 2026
Resilient capacity, explained

Installed capacity is what you bought. Resilient capacity is what you can count on.

Resilient capacity is the IT load a site can still carry after its worst single failure. It is the number that decides whether a site is safe, and how much more compute it can sell.

Design IT load5 MW
Power3 UPS modules · 2 MW each
UPS 1UPS 2UPS 3
6 MW installedUPS 3 fails: 4 MW of power left
Cooling4 units · 1.5 MW each
Unit 1Unit 2Unit 3Unit 4
6 MW installedUnit 4 fails: 4.5 MW of cooling left
Resilient IT capacity4 MWThe lower of power and cooling · 80% of design
3.7 MW runningLooks spare: 1.3 MW
Safe to add: 0.3 MWAt risk if a UPS fails: 1.0 MW
Illustrative
Nominal IT capacity5.0 MW
Resilient IT capacity4.0 MW
Current IT load3.7 MW
Resilient headroom0.3 MW
Resilient capacity ratio80%

Recalculated when a unit goes into maintenance, a chiller derates on a hot day, or the site changes.

What makes the number trustworthy

Built the way your engineers would check it.

Every level, calculated on its own.

Site, hall and air zone. Never added up from below, because shared plant breaks the sum.

Real capacity, not nameplate.

Cooling from measured airflow and temperatures.

Maintenance-aware.

A unit out for service counts as unavailable. The screen says "redundancy lost".

Explains itself.

"If UPS-2 fails, today's load is supported. At 4.4 MW, a 400 kW shortfall."

Single points of failure named.

A single transfer switch or single-fed row, listed next to the figure.

The next limit, too.

Fix one constraint and see what limits you next, before you spend.

The device graph

Paths matter as much as spare units.

The device graph maps what feeds, cools and backs up what: power paths A and B, chilled and condenser water, coolant loops and air zones. When a unit or path fails, aQ Resilience checks that a healthy path remains everywhere.

UPS roomHall 1Hall 2Chiller plantCRAH-2 in maintenancePower paths A and B, from UPS to every rowWhich cooling unit serves which zoneRedundancy groups, each with its design rule
Three relationships the graph keeps for every unit.CRAH-2 fails. Its zone is now cooled by CRAH-1 alone.Illustrative
Efficiency with a cause

Efficiency, from the meters. Waste, with a cause.

Every meter is tagged IT or facility, so PUE, WUE and CUE calculate themselves to ISO/IEC 30134. Each chiller, CRAH, pump and tower is then compared with its expected performance, so waste comes with a reason and a value.

PUE1.30
WUE1.69L/kWh
CUE0.92kgCO2e/kWh
Where the overhead goesWaste with a detected cause
Chillers38%
CRAH fans17%
UPS losses16%
Condenser pumps14%
Cooling towers9%
Lighting and BMS6%
Illustrative
Evaporative cooling lowers PUE but raises WUE. aQ Resilience always shows them side by side.
Water, with aQ WaterGuardTower makeup, evaporation, blowdown and leaks. Every litre accounted for.
What-if

What if...? Test it before it happens.

Scenarios run on a copy of your site, never on the live view, and never send a command.

Pass
Resilient headroom0.18 MW
Energy vs baseline+0.4%

N+1 holds. Tightest: hall air.

Illustrative
Recommend, approve, verify

AI that recommends. People who decide.

  1. TriggerSchedule, alarm or weather.
  2. AI evaluatesStrategies, resilience calculator, what-if.
  3. GuardrailsSafe limits, keep headroom.
  4. You approveA person decides.
  5. Applied through your BMSWhere control is enabled, logged.
  6. Verified at the meterAgainst the baseline.
Recommendation · Hall 1 chiller plant

Raise the chilled-water supply setpoint by 2 K

Why
Hottest rack inlet is 21.8 °C, inside the ASHRAE band with room to spare. Warmer chilled water lowers chiller lift.
Plan
Raise in 0.5 K steps, watching the hottest rack inlets. Stop if any inlet passes 25 °C or a CRAH valve reaches 95% open.
Impact
Energy -6.7 kW (about 161 kWh/day) · Water -239 L/day · Resilience: no change
Illustrative

Guardrails sit outside the AI. Every number comes from a calculation, never from a language model. Every step is in the audit log.

Alarms

Alarms that close the loop.

  1. Open
  2. Assigned
  3. In progress
  4. Fixed: verified by data
Hot server inletHall 1 · Row 4 · 29 °C
Coolant leakCDU-2 · drip tray
Redundancy lostHall 2 cooling now at N
Illustrative

A ticket closes only when the readings show the problem is fixed.

Works with what you have

Keep your BMS. Keep your DCIM. Add the answers.

Read what is there.

BMS and meters over BACnet, Modbus and MQTT. DCIM, EPMS and SNMP connectors are being built with our design partners.

Fill the gaps.

A small sensor kit: rack inlets at three heights, aisle pressure and humidity, leak rope, flow and thermal meters.

Run where you need.

On cloud or on site. Read-only first. Local controls always take priority.

SOC 2 Type 2ISO/IEC 27001ISO 9001:2015AWSNVIDIA Inception member
Who it is for

Built for the sites that need it most.

Data center aisle lit in blue

Legacy data centers.

Raised floors, patched redundancy, drawings that no longer match, and AI racks arriving anyway.

Grid of blue lights

Cooling and water-heavy sites.

Evaporative towers in hot or water-stressed regions, and liquid loops added to old plant. Stay resilient on the hottest day.

Platform

One platform, from offices to data halls.

aQ Resilience runs on Milvian AI's platform (Aqueduct), live across energy, water and air at 300+ sites and 80M+ sq ft.

Fortune 10 retailer

water program on Aqueduct

A top 25 US airport

running water intelligence on Aqueduct

80M+ sq ft

of real estate on Aqueduct

Design Partner Program

Become a design partner.

A small group of data center operators is shaping aQ Resilience with us. Start read-only, on one hall, for 90 days.

  • A device graph of your site.
  • Resilient capacity and headroom by level.
  • Single points of failure.
  • PUE, WUE and CUE baseline with waste by cause.
  • Ranked recommendations.
  • Roadmap influence and partner pricing.
Apply for the Design Partner Program

Pick a time for a 30-minute call. Tell us your site type, IT load and cooling, and we will confirm fit within two working days.

Questions

Common questions

It is the lowest of the power and cooling capacity left once the largest single unit or path is out, without overloading anything that remains. Take a 5 MW design with three 2 MW UPS modules: losing one leaves 4 MW. See the worked example.

DCIM lists the assets and power chain you have. aQ Resilience works out live, redundancy-aware headroom across power, air, liquid cooling, the chiller plant and water together, including units in maintenance and hot-day derating. It sits alongside your DCIM. See integrations.

Not on its own. Pilots start read-only. A recommendation needs a person to approve it and goes through your BMS, which stays in charge, and every step is kept in the audit log. See how agentic AI works within limits you set.

PUE, CUE and WUE follow ISO/IEC 30134-2, -8 and -9, built from IT and facility meters rather than estimates. Thermal limits follow ASHRAE TC 9.9 guidance for allowable rack inlet temperatures. See PUE in the glossary.

Yes. CDU supply and return temperatures, flow, pressure, dew-point margin and leaks are monitored, and each CDU group counts toward resilient capacity in the same way an air cooling unit does. See aQ WaterGuard for towers and coolant loops.

Milvian AI is SOC 2 Type 2 and ISO/IEC 27001 certified. Local controls always take priority, and a lost connection leaves equipment in a safe state. Read more on trust and security.

Ask AI about aQ ResilienceOpens your assistant with a prepared question.

Find the safe megawatts you already have.