EU EPBD building automation and monitoring, by article

The recast Energy Performance of Buildings Directive, (EU) 2024/1275, requires building automation that monitors, logs and analyses energy in larger non-residential buildings, and sets minimum performance standards for the worst ones. Aqueduct supplies that monitoring and the data behind it.

Powered by aQ Assure and aQ EnergySmart
Condenser fans seen from above
Site performance · this quarter
-8.4% vs expected
Weather normalizedBelow baseline
Demo data
Peak demand today
612 kW
Contracted 650 kWChillers sequenced
Demo data

Who it applies to

The directive binds member states, which had to transpose it by 29 May 2026. Owners then meet it through national law. Non-residential buildings are caught by the rated output of their heating or air-conditioning systems, the worst performing share of the stock faces minimum standards, and every new building must be zero-emission by 2030.

Penalties are set nationally. The directive only requires them to be effective, proportionate and dissuasive.

The articles

What the directive requires, and the data behind it

Article numbers refer to Directive (EU) 2024/1275 as published on EUR-Lex.

RequirementWhat it asks forData Aqueduct supplies
Art. 13(9), building automationBACS in non-residential buildings over 290 kW by end 2024 and over 70 kW by end 2029, where feasible.Meter, BMS and sensor data on one model of each building.
Art. 13(10), BACS functionsContinuously monitor, log and analyse energy, benchmark it, detect efficiency losses and inform the facility manager.Interval energy per system with weather-normalized baselines and fault alerts routed to the team.
Art. 13(10), indoor environmentBACS able to monitor indoor environmental quality from 29 May 2026.CO2, temperature, humidity and particulates per zone from aQ AirSafe.
Art. 13(12), lighting controlsAutomatic lighting with occupancy detection over 290 kW by end 2027.Occupancy and lighting circuit data showing lights off in empty zones.
Art. 16, data exchangeOwners, tenants and managers get access to building system data.Exports and APIs by building, meter and period.
By the numbers

Dates that matter

2030 / 2033

Non-residential buildings must be better than the worst 16% threshold by 2030 and the worst 26% by 2033 (Art. 9).

Source: Directive (EU) 2024/1275
1 Jan 2028

New buildings owned by public bodies must be zero-emission; all new buildings from 1 January 2030 (Art. 7).

Source: Directive (EU) 2024/1275
31 Dec 2029

The automation threshold falls from 290 kW to 70 kW of rated output (Art. 13(9)).

Source: Directive (EU) 2024/1275
Standards and regulations

Related standards

CSRDISO 50001 EN ISO 52120-1BREEAM
Trusted at scale
Read the case studies
Deployed275+

sites in 21 countries run on Aqueduct.

Healthcare22 hospitals

and 9 clinics in one of India’s top hospital chains.

AirportsA top 25

US airport running water intelligence on Aqueduct.

Real estate20M+ sq ft

of commercial real estate under Aqueduct.

Manufacturing300 acres

FMCG manufacturing campus.

Food and dairyMajor dairy

operations run on Aqueduct.

Questions

Common questions

Not necessarily. Article 13(10) asks for continuous analysis, benchmarking and detection of efficiency losses, which many BMS installations do not do. Aqueduct adds those functions on top of the BMS.

An optional EU scheme under Article 15 that rates a building's ability to adapt its operation to occupants and the grid. Member states decide whether to use it, and continuous monitoring and controls of the kind Article 13 describes are among the functions it assesses.

Each member state sets kWh per square meter thresholds from its own stock as of 1 January 2020, so the numbers differ by country. Metered energy shows which side of the line a building sits.

Yes, as a capability. Automation systems installed under Article 13 must be able to track indoor conditions, not only energy. aQ AirSafe sensors fill that gap zone by zone where the existing BMS measures only temperature. See IAQ monitoring.

See Aqueduct on your own facility.

Bring a site, a utility bill or a question. We will show you where the loss is.