GHG Protocol

GHG Protocol Scope 1 and 2 inventories from metered energy

The GHG Protocol Corporate Standard, from WRI and WBCSD, is the accounting method most corporate emissions reporting uses. Scope 1 and 2 start from fuel, electricity, steam, heat and cooling consumed at each site. Aqueduct supplies those quantities from meters, with the trail an assurer follows.

Powered by aQ Assure and aQ EnergySmart
Condenser fans seen from above
Site performance · this quarter
-8.4% vs expected
Weather normalizedBelow baseline
Demo data
Peak demand today
612 kW
Contracted 650 kWChillers sequenced
Demo data

Who it applies to

Any company building a corporate greenhouse gas inventory. The standard is voluntary, but disclosure programs such as CDP ask which method was used, and ESRS E1 under the CSRD requires Scope 2 both ways.

Companies with operations in markets that offer contractual instruments, such as renewable energy certificates or supplier-specific rates, must report Scope 2 twice: on a location basis and on a market basis.

Corporate Standard and Scope 2 Guidance

What the inventory requires

Chapter references to the Corporate Standard (revised edition) and the 2015 Scope 2 Guidance. Your inventory owner and assurer sign off.

RequirementWhat it asks forData Aqueduct supplies
Chapter 3, organizational boundariesConsolidate by equity share, financial control or operational control.Sites and meters grouped by entity, so any boundary can be drawn.
Chapter 4, Scopes 1 and 2Report Scope 1 and Scope 2 separately, at a minimum.Fuel and gas meters for Scope 1, electricity and thermal meters for Scope 2.
Scope 1, fugitive emissionsIncludes refrigerant leaks from cooling and refrigeration.Compressor and refrigeration faults that point to leaks, for the service records.
Scope 2, two methodsLocation-based and market-based totals, with quality criteria for instruments.Metered electricity by site and month, the quantity both methods share.
Chapter 5, base yearChoose a base year and recalculate it for structural changes.Base year consumption held per site, so acquisitions and sales can be adjusted.
By the numbers

What is changing

Q4 2028

Estimated publication of a merged Corporate Standard covering Scopes 1, 2 and 3, co-branded with ISO; draft for consultation expected Q2 2027.

Source: GHG Protocol development plan, July 2026
Jan 2026

Public consultation on revised Scope 2 rules closed on 31 January 2026.

Source: GHG Protocol
Standards and regulations

Related standards

CDPCSRDSECR BRSR Core
Trusted at scale
Read the case studies
Deployed275+

sites in 21 countries run on Aqueduct.

Healthcare22 hospitals

and 9 clinics in one of India’s top hospital chains.

AirportsA top 25

US airport running water intelligence on Aqueduct.

Real estate20M+ sq ft

of commercial real estate under Aqueduct.

Manufacturing300 acres

FMCG manufacturing campus.

Food and dairyMajor dairy

operations run on Aqueduct.

Questions

Common questions

Bills cover the account, not the site or entity, and their periods rarely match the reporting year. Interval meter data can be cut to any boundary and any period without estimates.

Aqueduct supplies the activity data, the kWh and fuel quantities by site and month. Emission factors and contractual instruments are applied in your carbon accounting tool or by a consultant, so factor choices stay with whoever owns the inventory.

The consultation proposed tighter matching of contractual instruments to consumption in time and location. If adopted, hourly consumption data per site would matter more, and Aqueduct already stores interval data at that resolution or finer.

Yes. Leaked refrigerant is a fugitive Scope 1 emission, and most inventories estimate it from the gas topped up during servicing. Aqueduct flags compressor behavior that points to low charge, such as long run times for the same cooling, so leaks are found and logged sooner.